| Apotex Corp is voluntarily recalling two (2) batches of Enoxaparin Sodium Injection, USP to consumer level due to a packaging error resulting in some syringes barrels containing 150 mg/mL markings (corresponding to 120 mg/0.8mL strength) instead of 100 mg/mL markings (corresponding to 100 mg/mL strength) on the syringe barrel and vice versa. The packaging error was discovered during a customer complaint investigation. To date, Apotex has not received any reports of adverse events related to use of these two batches. The affected product is manufactured by Gland Pharma Limited, Hyderabad, India. Health Hazard Assessment: Incorrect syringe barrel marking could lead to miscalculation and inaccurate dose administration to patients. In one recalled batch (batch CS008, strength 100 mg/mL), if a consumer used a 150 mg/mL concentration packaged in a barrel corresponding to a l00 mg/mL concentration, patients could receive 3.75 mg of Enoxaparin, instead of 3 mg of Enoxaparin. In another recalled batch (batch CT003, strength 120 mg/0.8mL), if a consumer used a 100 mg/mL concentration packaged in a barrel corresponding to a 150 mg/mL concentration, patients would receive 2 mg of Enoxaparin rather than 2.5 mg of Enoxaparin. Accidental overdosage following administration of enoxaparin sodium injection may lead to bleeding complications. Alternative, if the dose administered is less than prescribed, the patient may be subject to developing some blood clotting conditions. | | | |